Component Objects
Command String
Command String blocks allow RS-232 control of
external devices via NEXIA's Serial port. Control
input nodes along the top of the block produce
corresponding serial commands, when triggered
by control output nodes on other components
within the design. Commands can also be initiated
using the command button which appears within
the control dialog box. Command ID allows the
command/button to be named. Command String
allows the appropriate character string to be
entered. Update sends the character string to be
stored in NEXIA device memory.
Unlike most other blocks, multiple control output nodes may be connected
to a single control input node on a Command String block. Control Dialog
Boxes for Command String components can be minimized to create user
control surfaces (see Customizing Component Objects
).
NOTE: Some command strings may need to output nonprintable characters. The strings
themselves must be printable, so this is done by including three-character sequences in the
command string. The first will be a tilde, the second and third hex digits. To include a carriage
return and line feed pair, for example, in the string, include the text ~0d~0a (either case may be
used). A tilde may only be included by using the sequence ~7E (or ~7e) for the tilde character
itself.
131