Nexia-Manual-A4
198
If a Nexia does not have a system loaded into it, you can set the IP Address via the RS-232 port.
Example: SET 0 IPADDR 192.168.1.101 <LF>. If there is no NEX file in the Nexia, and the
command is typed correctly, Nexia will send back a ‘+OK’ response. You will need to power cycle
the Nexia for the new IP Address to take effect. As stated above, Nexia will output the IP Address
when powered up, or you can use the GET IPADDR command mentioned above.
Reset
In rare instances it may become necessary to reset the Nexia device. A reset can be
accomplished through the device maintenance screen, and this is the desired method for a reset.
However, there is a reset command available via the RS-232 port. Simply type: CLEAR 0
DEVCONFIG <LF> and the device will be reset.