The Attribute defines the portion of the DSP block to be controlled (fader level, crosspoint mute
etc). The following tables show whether each NTP Attribute supports SET/SETL, GET/GETL,
INC, and DEC Commands
, as well as the Value range that the Attribute will accept.
Index1/Index2 determines whether Index1
, Index2 or BOTH are needed for a NTP String to be
complete.
NTP Strings can address: (click on the links to view the tables in each topic)
Input/Output Blocks
Mixer Blocks
Equalizer Blocks
Filter Blocks
Crossover Blocks
Dynamics Blocks
Router Blocks
Delay Blocks
Control Blocks
Meter Blocks
Generator Blocks
Input/Output Blocks
The following table of Attributes is valid for all Nexia input blocks except Nexia PM Stereo Line
Inputs, Nexia TC & Nexia VC AEC Inputs, and Nexia TC & Nexia VC Pre-AEC Inputs.
Analog Inputs Attribute Commands Index Value Range
Input Gain INPGAIN
SET, SETL, GET, GETL,
INC, DEC
1
0, 6, 12, 18, 24, 30, 36,
42, 48, 54, 60, 66
Input Level INPLVL
SET, SETL, GET, GETL,
INC, DEC
1 -100 ~ 12 *
Phantom Power PHPWR SET, GET 1 0 = off
1 = on
Input Mute INPMUTE SET, GET 1 0 = unmuted
1 = muted