Page view 27
Nexia-Manual-A4
A list displays all defined control items, each with a Channel Number and customizable Control
Label. The New button creates a control item in the list, and the user is prompted to either accept
the default label or enter a new one. Rename allows the user to change the Control Label of the
selected control item. Delete removes the selected control item from the list. Move Up and Move
Down modify the order of the control items in the list, giving the user the ability to control the
display order of the control items on the RED-1 panel.
Each control item may have a Level Control assignment, a Logic Control assignment, or both.
Level Control
Object Code selects from a list of blocks found in the layout, and the Instance ID is entered
automatically, if known. Control ID selects from a list of available levels within the chosen block.
Logic Control
Logic Index specifies which logic connection point, if any, on the RED-1 block will be triggered
when that control item is selected.
Once the RED-1 block has been programmed with control items, the Select and Up/Down Arrow
buttons at the bottom of the control dialog box may be used to mimic how the control will function
from the physical panel.
Control dialog boxes for RED-1 devices may be minimized to create user control surfaces (see
Customizing Component Objects).